Roof detail pitched roof to high wall 01 030 0751.
Brick wall to roof detail.
Flat roof and flashing against brick wall install base flashing under shingles or over metal roofing material.
If the roof runs flat up against the brick wall you must install the roof side of the flashing either under the last layer of shingles or over the roof material if it is metal.
Roof detail high wall low roof 01 030 0804.
The current flashing details in the 2013 international residential code irc for sloped roof wall intersections are very difficult to construct.
Follow the photo for illustrated instructions.
Caldwell contracting is a roofing contractor and disclaims liability for any difficulties or loss due to lack of knowledge of masonry and framing systems.
That lip is then set into a reglet or groove in this case cut into the mortar joint of the brick wall above.
Wall system brick block wall 2in spray foam.
Brick veneer cmu backup rigid insul.
There have always been problems with the flashing details at the roof to wall intersections of head walls rake walls and chimneys especially if brick or stone veneer or stucco is used.
To install the roof wall flashing above the builder bent the top edge of the flashing into a 90 degree lip about 2 cm in width.
Roof to wall intersections.
Detail for attachment to metal panel siding or fascia.
To wall sloped roof no overhang ledger support.
W taped joints veneer ties.
As a result most typical construction does not use any type of through the wall flashing which results in leaky wall complaints.